Skip to main content

Noritesoution

Flow Control, Zero Compromise

From municipal water to industrial flow systems — total reliability starts here.

From deep wells to pipelines and wastewater treatment, Norite delivers efficiency, durability, and trust in every drop.

Micro-resistance slow closing check valve

Slow-Closing & Water-Hammer Protection

When the flow stops, the valve closes slowly instead of slamming shut, preventing water-hammer and pressure surges, thus protecting pipelines, pumps and connected equipment.

Low Resistance Flow Path & Energy-Saving

Compact design and smooth flow path minimize pressure drop — efficient for systems requiring stable flow and low energy consumption.

Compact, Lightweight & Easy to Install/Maintain

Smaller size and lower weight make installation and maintenance easier — ideal for projects with limited space or tight installation conditions.

Reliable One-Way Flow & Good Sealing Performance

Provides reliable one-way flow prevention and tight sealing when closed, preventing backflow and leakage in pipelines.

Smooth Operation, Low Noise, Long Service Life

Slow closing and damping mechanism ensure smooth, low-noise operation and reduced mechanical stress — contributing to long service life and system reliability.

Need custom specifications? Our engineers are ready to help.
Call: +86 15090163952 | Email: lisa@noritesolution.com

Proven Results That Drive Your Bottom Line

Real performance data from our Valve installations across critical industries worldwide

100% Pressure Tested

Leak-Free Guarantee with Factory Hydrostatic Test

Tested under Class A sealing standard, across 10,000+ units.

20+ Years Lifespan

Long-Term Durability in Harsh Conditions

Proven performance in seawater, wastewater, and high-pressure pipelines.

8,000+ Valves Installed

Global Project Deployments

Including power plants, municipal water systems, and industrial zones.

99.5% On-Time Delivery

Reliable Manufacturing & Fulfillment

Backed by lean production and strict QC.

Certifications & Standards

Technical Specifications

Engineered for optimal performance across a wide range of industrial applications

Model:

Size Range:

HH44X ,HH47X,HH48X

DN50 – DN1200,  2”-48”

Pressure Rating:

Standards:

PN10 / PN16/PN25;125LB/
150LB

EN 594,,BS5153

Media:

Max Temperature:

Water and neutral liquids

≤ 80°C

Body Material:

Wedge Material:

Ductile iron, carbon steel, stainless steel

Ductile iron GJS-500-7 (GGG-50),SS304,SS316, Aluminum bronze,Duplex stainless steel

Stem Material:

Sealing:

Stainless steel

EPDM / NBR

Connection:

Certifications:

Flanged to EN1092-2,ANSI B16.5,BS4504

WRAS /ACS Approved for drinking water

Water Supply & Drainage Systems
Ideal for municipal or building water supply and drainage systems — installed at pump outlets or main pipelines to prevent backflow and water hammer.

Pumping Stations & Pump Outlets
For pumping stations or water/wastewater pumping systems with frequent start-stop cycles — protects pumps and pipelines from pressure shocks.

Sewage / Wastewater / Industrial Wastewater Systems
Used in wastewater treatment plants, industrial effluent pipelines or sewage systems — prevents backflow, hydraulic shock, and ensures stable operation under corrosive media.

High–rise / Building Plumbing Systems
Suitable for high-rise or large building water systems — safe backflow prevention and pressure stabilization during pump stop/start or supply disruptions.

HVAC / Heating & Cooling Circulation Systems
In HVAC, circulation water or recirculation pump systems — ensures stable and quiet operation and prevents reverse flow.

Seawater / Coastal Water / Desalination Intake–Discharge Lines
Suitable for seawater intake/discharge, desalination plants or coastal water systems — provides backflow prevention, water hammer protection, and corrosion resistance

Testing Process

From raw materials to finished products, NORITE maintains 100% testing coverage, ensuring that every valve and pump you receive is built to last — safe, stable, and globally certified.

High-Pressure Shell & Seat Testing

Pressure Testing

Each valve undergoes rigorous pressure and hydrostatic testing prior to shipment to verify body strength, sealing integrity, and pressure stability—ensuring zero leakage and long-term reliability in field operation.

Torque & Operational Precision

Torque and Functional Testing

Confirming operating performance and precision.

Accelerated Cycle Life Simulation

Cycle Life Testing

Simulating long-term use under real working conditions.

Coating Thickness & Adhesion Test

Coating & Corrosion Resistance Testing

Validating surface protection and durability.

Material Spectroscopy & CMM Analysis

Dimensional & Material Analysis

Using spectrometers and coordinate measuring machines (CMM) for accuracy.

Full Traceability & Serialization

Traceability - Unique product code

Each product leaving our factory is accompanied by a full inspection report and a unique serial number, enabling full traceability and lifetime quality tracking.

Real Project Cases

Proven performance in critical applications worldwide – see our valves in action

Kheng Grou Dam

Owner:Direction de l’Aménagement Hydraulique (DAH)

This project not only represents an improvement in Morocco’s water infrastructure but also demonstrates our supply capabilities and expertise in large-scale water projects.

We supplied the dam with products including electric gate valves, hydraulic butterfly valves, detachable couplings, and vent valves.  The project is still under construction, and our full-cycle service continues.

Get Your Custom Quote

Our technical experts will analyze your requirements and provide a tailored solution with detailed specifications and competitive pricing.