The SLOW double suction pump is designed for high-flow transfer of clean water and compatible neutral liquids in municipal water supply, intake stations, cooling-water circulation and irrigation projects.



The pump uses a double-volute casing and double-suction impeller to balance axial forces, reduce bearing loads, and ensure longer, more stable operation.
The optimized inlet flow eliminates vortex formation, ensures uniform impeller suction, minimizes hydraulic losses, and provides smooth and efficient performance.
The fully sealed shaft prevents liquid contact and corrosion, while replaceable wear rings protect the casing and reduce maintenance costs.
The self-aligning pump cover and flexible inlet/outlet configuration allow easy installation and reduce space requirements.
The double-suction impeller minimizes axial forces, and high-quality components ensure durable, low-vibration, and reliable long-term performance.
Need custom specifications? Our engineers are ready to help.
Call: +86 15090163952 | Email: lisa@noritesolution.com
Published series envelope for preliminary selection. Flow, head, port size, materials, speed and motor must be confirmed against the selected SLOW model curve and data sheet.









The SLOW is a horizontal split-case, double-suction centrifugal pump for high-flow clean-water and compatible neutral-liquid duties. Liquid enters both sides of the impeller, while the double-volute casing and double-suction impeller help balance hydraulic forces and reduce bearing load.
Eight product images from the supplied SLOW material are shown below. Pump casing, motor, coupling, flange and base details vary by size and approved project configuration.








| Pump type | Horizontal split-case, double-suction centrifugal pump |
|---|---|
| Flow | 68–6,276 m³/h* |
| Head | 9–306 m* |
| Motor power | 0.18–160 kW* |
| Inlet / outlet size | 150–600 mm* |
| Voltage / frequency | 220 / 380 / 460 / 480 / 660 V; 50 or 60 Hz* |
| Liquid temperature | Up to 120°C*, subject to seal, material and pressure confirmation |
| Published speeds | 740 / 990 / 1,480 / 2,960 r/min |
| Protection / insulation | IP68 / Class F* |
| Working pressure | Up to 1.6 MPa* |
| Material families | Cast iron; stainless steel 304, 316 and 316L; duplex 2205 and 2507; 904L, subject to model availability |
*Maximum figures are not simultaneous guarantees for one model. Confirm the selected pump, motor, seal, pressure, temperature and material combination.
Liquid enters the impeller eye from both sides. The rotating impeller increases liquid velocity; the split casing and volute convert part of that velocity into pressure and guide the liquid to discharge. The double-entry flow path helps balance axial hydraulic forces, while the double-volute casing reduces radial loading for stable high-flow operation.
Double-suction impeller, split casing and double-volute passage distribute inlet flow and reduce axial and radial loading.
The sealed shaft arrangement limits liquid contact, while replaceable wear rings protect major casing surfaces.
Lower hydraulic loading supports stable operation. The split casing provides access for inspection without disturbing connected pipework, subject to model design.

Use the published series chart to screen candidate pump sizes. Then verify the selected size on its model-specific Q-H curve, including efficiency, absorbed power, NPSHr and the preferred operating region.


High-flow clean-water transfer, intake stations and compatible drainage duties sized from the actual system curve.
Cooling-water and compatible process-water loops after liquid, solids, material and seal review.
Irrigation, distribution networks and long-distance water transfer within the selected model curve.
Cooling-water and utility circulation with confirmed NPSH margin, driver and control method.
Only with project-specific hydraulic, corrosion, material, seal and cathodic-protection review.
High-flow compatible water duties where installation, vibration, corrosion and service access are confirmed.
The Mambu Branco project in São Paulo State, Brazil addressed insufficient intake capacity and seasonal pressure on the regional network. The works included new intake facilities, pumping stations and approximately 66 km of water-supply pipelines.

Vertical single-stage pumps, vertical two-stage pumps and horizontal centrifugal pumps operating as one integrated water-supply system.
Increased water-supply capacity and improved reliability during peak summer demand.
Depending on model and duty, SLOW configurations may be available in cast iron, stainless steel 304, 316 or 316L, duplex 2205 or 2507, and 904L. A material grade alone does not establish chemical compatibility.
Review liquid composition, chloride content, pH, concentration, temperature, solids and cleaning chemicals. Request a project-specific bill of materials identifying the casing, impeller, shaft-related parts, fasteners, mechanical seal and elastomers.
A double suction pump feeds liquid to both sides of one impeller. This supports high-flow duties and helps balance axial hydraulic force.
An end-suction pump normally feeds the impeller from one side. A double suction pump feeds both sides and is commonly selected for higher-flow water-transfer duties.
No. They are limits of the overall SLOW series envelope. The selected model curve defines the available flow-head combination.
The pump NPSHr must be compared with the system NPSHa with an adequate margin to reduce cavitation risk.
Only after liquid chemistry, chloride level, wetted materials, seal, fasteners and corrosion allowance are reviewed for the project.
The series material lists both frequencies, but the selected motor and model-specific performance curve must match the actual site supply.
Do not assume self-priming. Confirm flooded-suction or priming arrangements, suction lift, air evacuation and NPSHa for the installation.
Send flow points, total head, suction conditions, liquid data, temperature, power supply, material preference, quantity, destination and required standards.
Flow Rate:
Head:
68-6276m3/h
≤9-306m
Motor power:
Rated voltage:
0.18-160kw
220/380/460/480/660V
Frequency:
Diameters of the pump’s inlet and outlet:
50Hz/60Hz
Water temperature:
Speed:
≤120℃
740r/ min、990r/ min、1480r/ min or 2960r/ min
Protection class::
Insulation class:
F
Pressure Rating:
pump material:
≤1.6 MPa
Cast Iron, SS304/SS316/SS316L/
SS2205/SS2507/904L
/Bzone
Main pipelines for urban water supply
Secondary booster pump stations
Stormwater drainage and flood control systems
Sewage treatment plants (clean water transfer or reuse systems)
Cooling water circulation in power plants, steel mills, chemical plants
Paper mill water systems
Industrial neutral liquid or process water delivery
Large-area farmland irrigation networks
Canal water lifting stations
Water diversion and inter-basin transfer projects
Circulating cooling water in thermal or nuclear power plants
Hot water circulation systems in district heating networks
Coastal seawater intake stations
High-flow intake systems for pre-treatment and cooling
Port drainage and water transfer systems
Onboard cooling water or ballast water systems for ships



Use this split-case double suction pump where your project needs high flow with stable hydraulic performance: municipal water supply and drainage, raw-water intake, industrial cooling-water loops, irrigation and water-transfer stations.

For municipal water supply, drainage, raw-water transfer and intake-station duties where high flow and stable suction conditions are required.

Reliable pumping solutions for manufacturing processes, cooling systems, and industrial fluid handling.

For power-plant and utility cooling-water circulation, where the final pump curve, NPSH margin, materials and motor selection must match the duty point.

Irrigation systems, water distribution networks, and agricultural pumping solutions for sustainable farming.

Urban water supply, sewage systems, fire protection, and building services for smart city infrastructure.

Specialized pumps for marine vessels, offshore platforms, and coastal infrastructure projects.
Municipal water-supply expansion reference. It illustrates the application environment and selection context; it is not a claim that SLOW pumps were installed in this project.

Customer/Owner: São Paulo state water and sewage companyWorking
The water resources in this area are tight and the existing water intake capacity is insufficient. New water intake pumping stations and pipeline networks need to be built to ensure reliable water supply. The project includes water intake stations, large pumping stations and 66 km of water supply pipelines.
Vertical single-stage centrifugal pumps, vertical bipolar centrifugal pumps, horizontal centrifugal pumps
Key indicators:Serving approximately 1.2 million people; The length of the pipeline is approximately 66 km; A combination of multiple pump types.
Achievements/advantages:Improve the problem of water shortage and enhance the reliability of water supply, especially during the peak summer period. The user group has benefited significantly.
Share required flow, total dynamic head, liquid, temperature, suction conditions, voltage/frequency, material requirement, quantity and destination. We will confirm the SLOW model, curve, motor and datasheet.